Table 1

Number of patients with damage and/or repair per number of readers agreeing

Total N with damageTotal repair,
N (%)
JSN repair,
N (%)
Erosion repair,
N (%)
Both,
N (%)
≥1 reader (one time point)462343/462 (74.2)101/343 (29.4)53/343 (15.5)189/343 (55.1)
≥2 readers (one time point)393141/393 (35.9)70/141 (49.6)44/141 (31.2)27/141 (19.1)
≥3 readers (one time point)32051/320 (15.9)32/51 (62.7)13/51 (25.5)6/51 (11.8)
≥3 readers (two consecutive time points)32017/320 (5.3)10/17 (58.8)7/17 (41.2)0 (0.0)
  • JSN, joint space narrowing.